產品展示CREx 020 50W, 100W (T5)
TECHNICAL DETAILS
Temperature class | T5 |
Ex Protection type EX II 2 GD Gases Dusts | Ex db IIC T5 Gb Ex tb IIIC T100°C Db IP66 |
Ambient temperature | -60 to +50 °C (-76 to +122 °F) |
Surface temperature | max. +100 °C (+212 °F) |
Heating element | high performance cartridge |
Connection | silicone cable (halogen-free) 3 x 0.75 mm2, length 1 m |
Connection PE | 0.75 to 2.5 mm2 |
Mounting | clip for 35 mm DIN rail, EN 60715 for heating body sizes 80 x 48 mm and 120 x 60 mm; screw fixing with 2 plug-on flanges for all heating body sizes, optional widthwise mounting |
Fitting position | vertical airflow (connection on bottom) |
Storage temperature | -60 to +85 °C (-76 to +185 °F) |
Operating/Storage humidity | max. 90% RH (non-condensing) |
Protection type/Protection class | IP66 / I (earthed) |
Approvals | EPS 16 ATEX 1 109 X IECEx EPS 16.0048X EAC |
Art. No. Magnet fixing | Screw flange fixing Art. No. Hole spacing X | Operating voltage | Heating capacity | Rec. pre-fuse T (time-delayed) | Dimensions (D x W x H) | Switch |
02051.0-00 | 225 mm | AC 230 V | 50 W | 0.5 A | 120 x 60 x 180 mm | 1.4 kg |
02051.9-00 | 225 mm | AC 120 V | 50 W | 1.0A | 120 x 60 x 180 mm | 1.4 kg |
- | 350 mm | AC 230 V | 100 W | 1.0A | 160 x 80 x 300 mm | 2.8kg |
- | 350 mm | AC 120 V | 100 W | 2.0 A | 160 x 80 x 300 mm | 2.8 kg |
TECHNICAL DRAWING