產品展示溫度控制器 STO 011STS 011
TECHNICAL DATA
TECHNICAL DETAILS
Switch temperature difference | 4K (±3K tolerance) |
Sensor element |
thermostatic bimetal |
Lamp typeContact type | snap-action contact |
Service life | l> 100,000 cycles |
Max. switching capacity | 250VAC, 10 (2) A / 120VAC, 15 (2) A DC 30W at 24VDC to 72VDC |
Max. inrush current | AC 16A for 10 sec. |
Connection | 2-pole terminal, clamping torque 0.5Nm max.: rigid wire 2.5mm2 (AWG 14) stranded wire11.5mm2 (AWG 16) |
Mounting | clip for 35mm DIN rail, EN 60715 |
Casing | plastic according to UL94 V-0, light grey |
Dimensions | 70 x 33 x 43mm |
Weight | approx. 50g |
Fitting position | variable |
Operating/Storage humidty | -45 to +80°C (-49 to +176°F) |
Protection type/Protection class | max. 90% RH (non-condensing) |
Protection type | IP20 |
1 When connecting with stranded wires, wire end ferrules must be used. Important note:The contact system of the regulator is subjected to environmental influences, thus the contact resistance may change. This can lead to a voltage drop and/or self-heating of the contacts.
The anti frost assurance is a symbol on the setting scale of the NC thermostat (STO 011) at +11°C. This setting assures closing of the switching contact before 0°C.
Setting range | Art. No. Contact breaker (NC) | Art. No. Contact maker (NO) |
0 to +60°C | 01115.0-00 | 01116.0-00 |
+32 to +140°F | 01119.0-00 | 01116.9-00 |
ANTIFROSTASSURANCE
The anti frost assurance is a symbol on the setting scale of the NC thermostat (STO 011) at +11°C. This setting assures closing of the switching contact before 0°C.
TECHNICAL DRAWING
Small Compact Thermostat STO 011 / STS 011